High-country-tek DVC80 Manual de usuario Pagina 69

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 170
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 68
P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools Page | 69
Press the Button Labeled "Dig_1".
In the Digital Input 1 window, enter the following information:
Name: Start
De-bounce Time: 20ms
Polarity: Active High
Toggle: No Toggle
Press the Button Labeled "PWM_1" in the Output Groups.
Set up the following Fields:
Output Selection: Single Coil Low Side
Process Selection: Enable Current Ramps
Low Side A Name: TurnMotor
Current P: 10
Current I: 10
Min Cur: 0 A
Max Cur: 1 A
Ramp Down: 5s
Ramp Up: 5s
High Side 1 Name: EndPulse
Close the PWM_1 and DVC10 windows and return to the
project screen.
Setup the Bubble Logic
Click the right mouse button in the project window and add a
logic sequence.
Double click on the Logic Icon.
Add 5 bubbles to the logic window. To add bubbles, click the right mouse
button and select "Add Bubble". To move a bubble, click the left mouse
button on it and move the mouse. To delete a bubble, click on it and press
the Delete key.
Add transitions to look like the picture. Transitions are the
paths between bubbles. To add transitions, click the right
mouse button on a bubble and select "Add Transition". Next,
click the left mouse button on the bubble you want the
transition to point to.