P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools Page | 54
Name.ProI Process Proportional Term Constant “I” 0 – 255
Name.ProItime Update / Integration Time 0.0 to 650.00 s
Name.Cur Current actual * CurGain = amps 0 – 3.5 amps
Name.RampCur Current ramped Currend*CurGain= amps 0 – 3.5 amps
Name.CurErr Current Error = RampCur – Cur 16 bit signed integer
Name.CurSumErr Current Error accumulated over time 0 – 65535
Name.CurP Current Proportional Term Constant “P” 0 – 255
Name.CurI Current Proportional Term Constant “I” 0 – 255
Name.MinCurA Minimum Current Coil A *.001 = amps 0 – 3.5 amps
Name.MaxCurA Maximum Current Coil A *.001 = amps 0 – 3.5 amps
Name.MinCurB Minimum Current Coil B *.001 = amps 0 – 3.5 amps
Name.MaxCurB Maximum Current Coil B *.001 = amps 0 – 3.5 amps
Name.Config Configuration Word – Output, Process,
Coil
Status LED
Name Description Range
BlinkCode
The Status LED blinks the amount of times equal to the number
written to this location. When the blinking is done, the value for this
location will be 0.
0 to 65535
Input/Output Functions
Name De
scription Range
Name.In
Changing this variable will update the "Name.Out"
variable by the BIOS after a delay of 10ms
0% to 100%
Name.Out The Output of the Transfer Function 0% to 100%
Name.X0 The X0 of the input/output function 0% to 100%
Name.X1 The X1 of the input/output function 0% to 100%
Name.X2 The X2 of the input/output function 0% to 100%
Name.X3 The X3 of the input/output function 0% to 100%
Name.X4 The X4 of the input/output function 0% to 100%
Name.X5 The X5 of the input/output function 0% to 100%
Name.X6 The X6 of the input/output function 0% to 100%
Name.X7 The X7 of the input/output function 0% to 100%
Name.Y0 The Y0 of the input/output function 0% to 100%
Name.Y1 The Y1 of the input/output function 0% to 100%
Name.Y2 The Y2 of the input/output function 0% to 100%
Name.Y3 The Y3 of the input/output function 0% to 100%
Name.Y4 The Y4 of the input/output function 0% to 100%
Name.Y5 The Y5 of the input/output function 0% to 100%
Name.Y6 The Y6 of the input/output function 0% to 100%
Name.Y7 The Y7 of the input/output function 0% to 100%
Power Supply
Name Description
Supply The Power Supply voltage. The value returned is in units of supply volts (sv)
Temperature
Name Description
DVC_Temperature Internal DVC5/7 controller temperature. The value returned is in units of
degrees C + 40. Therefore, –40 C is returned as 0.
Continuous Counter
Comentarios a estos manuales