P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools Page | 51
Name.LOS Loss of Signal flag set after time out. For
Universal Pulse inputs Only
False (Pulses ok), True (No
Pulse Input)
Name.RealRPM The Unsigned Integer Value of the RPM. For
Universal Pulse inputs Only
0 to 9999
Name.Counter Get/Set Unsigned Integer Value of the Counter.
Universal Pulse inputs Only
0 to 65535
Name.PulsesPerRev Get/Set Pulses Per Revolution 0 to 9999
Output Group Selected as Dual Coil High-Side
Name Description Range
(Low-Side/PWM) Name Set the state Current Target or
Process in percentage of min to max
current
0% to 100%
Name.Dir Set the coil to be PWM’d, *(use High
Side names to set the direction)
High-Side Odd # Name / High
Side Even # Name
Name.Enable Set the PWM to 0 or enable the PWM True [PWM Enabled], False
[PWM = 0]
Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil Short]
Name.Open Get the Coil Flag for Open Status Off [Coil Ok], On [Coil Open]
HSEven#Name.Rampup Set the ramp up rate (time to travel
from 0% to 100%)
0.0 to 65.00 s
HSEven#Name.Rampdown Set the ramp down rate (time to travel
from 100% to 0%)
0.0 to 65.00 s
HSEven#Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil Short]
HSEven#Name.Open Get the Coil Flag for Open Status Off [Coil Ok], On [Coil Open]
HSOdd#Name.Rampdown Set the ramp down rate (time to travel
from 100% to 0%)
0.0 to 65.00 s
HSOdd#Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil Short]
HSOdd#Name.Open Get the Coil Flag for Open Status Off [Coil Ok], On [Coil Open]
Name.Cur Current actual * CurGain = amps 0 – 3.5 amps
Name.RampCur Ramped Current*CurGain= amps 0 – 3.5 amps
Name.CurErr Current Error = RampCur – Cur 16 bit signed integer
Name.CurSumErr Current Error accumulated over time 0 – 65535
Name.CurP Current Proportional Term Constant
“P”
0 – 255
Name.CurI Current Proportional Term Constant
“I”
0 – 255
Name.MinCurA Minimum Current Coil A *.001 = amps 0 – 3.5 amps
Name.MaxCurA Maximum Current Coil A *.001 =
amps
0 – 3.5 amps
Name.MinCurB Minimum Current Coil B *.001 = amps 0 – 3.5 amps
Name.MaxCurB Maximum Current Coil B *.001 =
amps
0 – 3.5 amps
Name.Config Configuration Word –Output,
Process, Coil
1
Name is the actual name entered in the Input/Output configuration window.
2
Scale depends on Input Range (0 to 5 =.00489, 0 to 10 = .00977, 0 to 25ma = 0.02158 )