High-country-tek MVP-C Series Manual de usuario Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
021-MVP-Cxx-(D1) Rev A MVP-C-(D1) User Manual 10
Copyright © High Country Tek, Inc. 2013
MVP-Cxx-(D1) Valve Controller
Parameter List
The following table outlines the MVP-F parameters as well as the limits and units of measure for each parameter.
Parameter
Limits
Units
MVP-Cxx-xxx-(D1)
Version #
Mode
See Mode Description
Mode #
Minimum input
0 to 10.0
4 to 20.0
V
mA
Maximum input
0 to 10.0
4 to 20.0
V
mA
Minimum output
0 to 600
*
mA
Maximum output
0 to 600
*
mA
Ramp up
0.0 to 120.0
Seconds
Ramp down
0.0 to 120.0
Seconds
Dither frequency (MVP-C)
30 to 300,
(select OFF for 1000Hz)
Hz.
Dither frequency (MVP-Cxx-xxx-D1)
80 to 300,
(select OFF for 1000Hz)
Hz
Output current
mA
Supply voltage
Volts
Fault status
Fault
*
0 to 1.2A for 12A version, 0 to 2.5A for 25A version for MVP-C
*
0 to 2.5A for 25A version for MVP-Cxx-xxx-D1