High-country-tek HFS-3 Manual de usuario Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
Hydraulic Fan System Controller HFS-3-12v
11
Adjustment Guide:
NON-INVERTED valve control operation.
HFS-3-12v Plug top controller is now set.
Replace opaque lid carefully ensuring that seal is maintained.
Replace securing screw and tighten
Do not over tighten or lid damage is seen.
Unit is now ready for continuous application use.
Adjust Dither frequency to suit valve product being driven.
Fully Anti-clockwise = approx. 100Hz
Fully Clockwise = Approx.... 250Hz.
Set command to Zero Volts.
Isolate plug from +12VDC supply.
Vista de pagina 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 19 20

Comentarios a estos manuales

Sin comentarios