Quick Start Guide DVC Family The information in this publication is intended as a guide only, and HCT take NO responsibility for usa
6 I/O List to Hardware Definitions 6.1 Declare I/O When the flow charts are complete from chapter 5, above, start the Intella software and defin
Notice the bubbles are directly related to the flowchart steps, now the programmer needs to write code for the individual bubbles. This is a very si
7.1 EE memory when online (PLM) Double click on the EE memory Status icon on the main Program Loader Monitor window to activate this screen. EE mem
8 HCT Terminology and Definitions Always bubble – Time critical logic needs to be contained here because this bubble will be executed based on
PN 021-00154-QSG, Rev A.2 Quick Start Guide Page | 14 9 Safety is Everyone’s Responsibility Safe work pra
Manual Index: 1 Software Installation...3 1.1 System Req
1 Software Installation 1.1 System Requirements Windows XP Professional Windows Vista Business or Ultimate 40 megabytes of disk space to support a co
DVC10 Expansion Modules: DVC21 40 Sinking and Sourcing Digital Inputs DVC22 40 Sinking Digital Inputs DVC41 12 High Side Outputs for B
4 Basic List of Actions to Create your First Application The Intella programming environment allows the programmer to be creative in their programm
Wherever Possible Do the Following • Keep High Voltage AC cables separate from Low Voltage DC signal and power supply cables. • Use the largest pra
all 128 EEmem variables. Variables that aren’t used could be name EEmem_spare_89, or such. An exception would be a variable that is declared privat
5 Flowchart (Sequence of Operations) Example This example will demonstrate how to create a flowchart and Sequence of Operations. This example may
5.2 Define functionality steps Step #1 Assure engine rpm is above 1000rpm Assure high pressure, left wheel system < 2000psi